all
KFD2-RSH-1.2D.FL3 Relay Module by Pepperl-Fuchs
Pepperl-Fuchs1-channel signal conditioner, 24 V DC supply, Logic input 19 V DC ... 26.4 V DC, Recommended connectable voltage 50 V AC ... 230 V AC, 60 V DC ... ...
View full detailsKFD2-RSH-1.2D.FL2 Relay Module by Pepperl-Fuchs
Pepperl-Fuchs1-channel signal conditioner, 24 V DC supply, Logic input 19 V DC ... 26.4 V DC, Recommended connectable voltage 8 V DC ... 60 V DC, Relay contact ...
View full detailsKFD0-RSH-1.1E.1 Relay Module by Pepperl-Fuchs
Pepperl-Fuchs1-channel signal conditioner, 24 V DC supply (loop powered), Logic input 19 V DC ... 26.5 V DC, non-polarized, Relay contact output for energized t...
View full detailsKCD0-RSH-1.1E.1 Relay Module by Pepperl-Fuchs
Pepperl-Fuchs1-channel signal conditioner, 24 V DC supply (loop powered), Logic input 19 V DC ... 26.5 V DC, non-polarized, Relay contact output for energized t...
View full detailsKCD0-RSH-1.1D.4 Relay Module by Pepperl-Fuchs
Pepperl-Fuchs1-channel signal conditioner, 24 V DC supply (loop powered), Logic input 19 V DC ... 26.5 V DC, non-polarized, Relay contact output for de-energize...
View full detailsKFD0-RSH-1.4S.PS2 Relay Module by Pepperl-Fuchs
Pepperl-Fuchs1-channel signal conditioner, 24 V DC supply (loop powered), Logic input 20 V DC ... 26.5 V DC, non-polarized, Fail-safe relay contact output for d...
View full detailsKFD0-RSH-1.1D.F1 Relay Module by Pepperl-Fuchs
Pepperl-Fuchs1-channel signal conditioner, 24 V DC supply (loop powered), Logic input 19 V DC ... 26.5 V DC, non-polarized, Relay contact output for de-energize...
View full detailsKCD0-RSH-1.1D.1 Relay Module by Pepperl-Fuchs
Pepperl-Fuchs1-channel signal conditioner, 24 V DC supply (loop powered), Logic input 19 V DC ... 26.5 V DC, non-polarized, Relay contact output for de-energize...
View full detailsKFD0-RO-2 Relay Module by Pepperl-Fuchs
Pepperl-Fuchs2-channel signal conditioner, 24 V DC supply (loop powered), Logic input 15 V DC ... 30 V DC, non-polarized, Relay contact output, Up to SIL 3 acc....
View full detailsKFU8-UFC-1.D.FA Frequency Converter with Trip Values by Pepperl-Fuchs
Pepperl-Fuchs1-channel signal conditioner, Universal usage at different power supplies, Input for 2- or 3-wire sensors, NAMUR sensors or dry contacts, Input fre...
View full detailsKFU8-UFT-2.D Frequency Converter with Direction and Synchronization Monitor by Pepperl-Fuchs
Pepperl-Fuchs2-channel signal conditioner, Universal usage at different power supplies, Dry contact or NAMUR inputs, Input frequency 1 mHz ... 1 kHz, Current ou...
View full detailsKFU8-UFC-1.D Frequency Converter with Trip Values by Pepperl-Fuchs
Pepperl-Fuchs1-channel signal conditioner, Universal usage at different power supplies, Input for 2- or 3-wire sensors, NAMUR sensors or dry contacts, Input fre...
View full detailsKFU8-DWB-1.D Rotation Speed Monitor by Pepperl-Fuchs
Pepperl-Fuchs1-channel signal conditioner, Universal usage at different power supplies, Dry contact or NAMUR inputs, Input frequency 1 mHz ... 12 kHz, 2 relay c...
View full detailsKFU8-DW-1.D Rotation Speed Monitor by Pepperl-Fuchs
Pepperl-FuchsSpeed monitoring up to 40 kHz, 1 pre-select value with relay output and LED indicator, 2-, 3-, 4-wire and NAMUR sensors as well as rotary encoder c...
View full detailsKFD2-UFT-2.D Frequency Converter with Direction and Synchronization Monitor by Pepperl-Fuchs
Pepperl-Fuchs2-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Input frequency 1 mHz ... 1 kHz, Current output 0/4 mA ... ...
View full detailsKFD2-UFC-1.D Frequency Converter with Trip Values by Pepperl-Fuchs
Pepperl-Fuchs1-channel signal conditioner, 24 V DC supply (Power Rail), Input for 2- or 3-wire sensors, NAMUR sensors or dry contacts, Input frequency 1 mHz ......
View full detailsKFD2-SR2-2.W.SM Standstill and Rotational Direction Monitor by Pepperl-Fuchs
Pepperl-Fuchs2-channel signal conditioner, 24 V DC supply, PNP/push-pull, dry contacts or NAMUR inputs, Selectable frequency trip values, 2 relay contact output...
View full detailsKFD2-DWB-1.D Rotation Speed Monitor by Pepperl-Fuchs
Pepperl-Fuchs1-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Input frequency 1 mHz ... 12 kHz, 2 relay contact outputs, ...
View full detailsKCD2-SCS-2.SP SMART Transmitter Power Supply/SMART Current Driver by Pepperl-Fuchs
Pepperl-Fuchs2-channel isolated barrier, 24 V DC supply (Power Rail), Analog input (AI), Analog output (AO), Operates as transmitter power supply or current dri...
View full detailsKCD2-SCD-1.SP SMART Current Driver by Pepperl-Fuchs
Pepperl-Fuchs1-channel signal conditioner, 24 V DC supply (Power Rail), Current output up to 900 ? load, HART I/P and valve positioner, Lead breakage monitoring...
View full detailsKFD0-SCS-1.55 SMART Current Driver/Repeater by Pepperl-Fuchs
Pepperl-Fuchs1-channel signal conditioner, 24 V DC supply (loop powered), Current input/output 4 mA ... 20 mA, HART-IP or transmitter power supply, Low voltage ...
View full detailsKFD0-CS-2.50 Repeater by Pepperl-Fuchs
Pepperl-Fuchs2-channel signal conditioner, 24 V DC supply (loop powered), Current input/output 4 mA ... 20 mA, transmitter power supply, Accuracy 0.1 %, Reverse...
View full detailsKFD0-CS-1.50 Repeater by Pepperl-Fuchs
Pepperl-Fuchs1-channel signal conditioner, 24 V DC supply (loop powered), Current input/output 4 mA ... 20 mA, transmitter power supply, Accuracy 0.1 %, Reverse...
View full detailsKCD2-SCS-2 SMART Transmitter Power Supply/SMART Current Driver by Pepperl-Fuchs
Pepperl-Fuchs2-channel signal conditioner, 24 V DC supply (Power Rail), Analog input (AI), Analog output (AO), Operates as transmitter power supply or current d...
View full detailsKCD2-SCD-1 SMART Current Driver by Pepperl-Fuchs
Pepperl-Fuchs1-channel signal conditioner, 24 V DC supply (Power Rail), Current output up to 900 ? load, HART I/P and valve positioner, Lead breakage monitoring...
View full details