all
KFD2-SH-Ex1.T.OP Switch Amplifier by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (Power Rail), Input for approved dry contacts or SN/S1N sensors, Active voltage output, Relay contact ou...
View full detailsKFD2-SH-Ex1 Switch Amplifier by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (Power Rail), Input for approved dry contacts or SN/S1N sensors, Relay contact output, Fault indication ...
View full detailsKFD2-ER-Ex1.W.LB Conductive Switch Amplifier by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (Power Rail), Level sensing input, Adjustable range 1 k? ... 150 k?, Relay contact output, Fault relay c...
View full detailsKFA6-ER-Ex1.W.LB Conductive Switch Amplifier by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 230 V AC supply, Level sensing input, Adjustable range 1 k? ... 150 k?, Relay contact output, Fault relay contact outpu...
View full detailsKCD2-ST-Ex2 Switch Amplifier by Pepperl-Fuchs
Pepperl-Fuchs2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 active transistor outputs, Reversible mode of operation, Li...
View full detailsKCD2-SOT-Ex2 Switch Amplifier by Pepperl-Fuchs
Pepperl-Fuchs2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, 2 passive transistor outputs, Reversible mode of operation, L...
View full detailsKCD2-SOT-Ex1.LB Switch Amplifier by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR input, 2 passive transistor outputs, Usable as signal splitter (1 inp...
View full detailsKFD2-SL2-Ex2.B Solenoid Driver by Pepperl-Fuchs
Pepperl-Fuchs2-channel isolated barrier, 24 V DC supply (Power Rail), Output 45 mA at 11.7 V DC, Logic input, non-polarized, Up to SIL 2 acc. to IEC/EN 61508, H...
View full detailsKFD2-SL2-Ex2 Solenoid Driver by Pepperl-Fuchs
Pepperl-Fuchs2-channel isolated barrier, 24 V DC supply (Power Rail), Output 45 mA at 11.7 V DC, Logic input, non-polarized, Line fault detection (LFD), Up to S...
View full detailsKCD0-SD3-Ex1.1245.SP Solenoid Driver by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 12 V DC, Test pulse immunity, Housing width 12.5 mm, Connection v...
View full detailsKFD2-SLD-Ex2.1545-Y1 Solenoid Driver by Pepperl-Fuchs
Pepperl-Fuchs2-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 45 mA at 15 V DC, Line fault transparency (LFT), Test pulse immunity, Hous...
View full detailsKFD2-SLD-Ex2.1245-Y1 Solenoid Driver by Pepperl-Fuchs
Pepperl-Fuchs2-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 45 mA at 12 V DC, Line fault transparency (LFT), Test pulse immunity, Hous...
View full detailsKFD2-SLD-Ex2.1045-Y1 Solenoid Driver by Pepperl-Fuchs
Pepperl-Fuchs2-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 45 mA at 10 V DC, Line fault transparency (LFT), Test pulse immunity, Hous...
View full detailsKFD2-SLD-Ex1.13100 Solenoid Driver by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (Power Rail), Logic input, Output 100 mA at 13 V DC, Alternating outputs for the operation of solenoids ...
View full detailsKFD0-SD2-Ex2.1245 Solenoid Driver by Pepperl-Fuchs
Pepperl-Fuchs2-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 12 V DC, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm, ...
View full detailsKFD0-SD2-Ex2.1045 Solenoid Driver by Pepperl-Fuchs
Pepperl-Fuchs2-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 10 V DC, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm, ...
View full detailsKCD2-SLD-Ex2.1545-Y1.SP Solenoid Driver by Pepperl-Fuchs
Pepperl-Fuchs2-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 45 mA at 15 V DC, Line fault transparency (LFT), Test pulse immunity, Hous...
View full detailsKCD2-SLD-Ex2.1545-Y1 Solenoid Driver by Pepperl-Fuchs
Pepperl-Fuchs2-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 45 mA at 15 V DC, Line fault transparency (LFT), Test pulse immunity, Hous...
View full detailsKCD2-SLD-Ex1.1045 Solenoid Driver by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 45 mA at 10 V DC, Line fault transparency (LFT), Test pulse immunity, Hous...
View full detailsKCD0-SD3-Ex2.1545-Y1.SP Solenoid Driver by Pepperl-Fuchs
Pepperl-Fuchs2-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 15 V DC, Test pulse immunity, Housing width 12.5 mm, Connection v...
View full detailsKCD0-SD3-Ex2.1545-Y1 Solenoid Driver by Pepperl-Fuchs
Pepperl-Fuchs2-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 15 V DC, Test pulse immunity, Housing width 12.5 mm, Housing widt...
View full detailsKFD2-VM-Ex1.35.L Solenoid Driver by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (Power Rail), Output 15.3 V DC at 17 mA, 3 logic inputs with AND/OR logic, Service port for isolator fun...
View full detailsKFD0-SD2-Ex1.1180 Solenoid Driver by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 80 mA at 11 V DC, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm, ...
View full detailsKFD0-SD2-Ex1.10100 Solenoid Driver by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 100 mA at 10 V DC, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm,...
View full detailsKCD2-SLD-Ex1.1245 Solenoid Driver by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 45 mA at 12 V DC, Line fault transparency (LFT), Test pulse immunity, Hous...
View full detailsKCD2-SLD-Ex1.1065 Solenoid Driver by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 65 mA at 10 V DC, Line fault transparency (LFT), Test pulse immunity, Hous...
View full detailsKCD0-SD3-Ex1.1245 Solenoid Driver by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 12 V DC, Test pulse immunity, Housing width 12.5 mm, Up to SIL 3 ...
View full detailsKCD0-SD3-Ex1.1045 Solenoid Driver by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 10 V DC, Test pulse immunity, Housing width 12.5 mm, Up to SIL 3 ...
View full detailsKFD2-UT2-Ex2-1 Universal Temperature Converter by Pepperl-Fuchs
Pepperl-Fuchs2-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Usable as signal splitter (1 input and ...
View full detailsKFD2-PT2-Ex1-1 Potentiometer Converter by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (Power Rail), Potentiometer input, Voltage output 0 V ... 5 V, Lead resistance compensation adjustment, ...
View full detailsKFD2-WAC2-Ex1.D Strain Gauge Converter by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (Power Rail), Strain gauge input (full or half bridge), Output 0 mA ... ± 20 mA or 0 V ... ± 10 V, 2 rel...
View full detailsKFD2-PT2-Ex1-5 Potentiometer Converter by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (Power Rail), Potentiometer input, Current output 4 mA ... 20 mA, Lead resistance compensation adjustmen...
View full detailsKFD2-PT2-Ex1 Potentiometer Converter by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (Power Rail), Potentiometer input, Voltage output 0 V ... 10 V, Lead resistance compensation adjustment,...
View full detailsKFD0-CC-Ex1 Current/Voltage Converter by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (loop powered), Current or voltage input, Output: 4 ... 20 mA, Potentiometer or DIP switch selectable ra...
View full detailsKFD2-UT2-Ex2 Universal Temperature Converter by Pepperl-Fuchs
Pepperl-Fuchs2-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Usable as signal splitter (1 input and ...
View full detailsKFD2-UT2-Ex1 Universal Temperature Converter by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Current output 0/4 mA ... 20 mA, Sink o...
View full detailsKFU8-GUT-Ex1.D Temperature Converter with Trip Values by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, Universal usage at different power supplies, Thermocouple, RTD, potentiometer or voltage input, Redundant TC input, Cur...
View full detailsKFD2-GUT-Ex1.D Temperature Converter with Trip Values by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Redundant TC input, Current output 0/4 ...
View full detailsKFD0-TT-Ex1 Thermocouple Converter by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (loop powered), Thermocouple input, Output 4 mA ... 20 mA, Internal cold junction compensation, Sensor b...
View full detailsKFD0-TR-Ex1 RTD Converter by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (loop powered), 2- or 3-wire Pt100 RTD input, Output 4 mA ... 20 mA, temperature linearization selectabl...
View full detailsKCD2-UT2-Ex1 Universal Temperature Converter by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Current output 0/4 mA ... 20 mA, Sink o...
View full detailsKFD2-VR2-Ex1.500M Voltage Repeater by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input 0 mV ... ± 500 mV, Voltage output 0 mV ... ± 500 mV, Selectable up/downscale...
View full detailsKFD2-VR-Ex1.19-Y109129 Voltage Repeater by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input -10 V ... 10 V, Transmission frequency up to 50 kHz, Voltage output -10 V .....
View full detailsKFD2-VR-Ex1.12 Voltage Repeater by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input 0 V ... 9 V, Voltage output 0 V ... 9 V, Housing width: 20 mm, Number of cha...
View full detailsKFD0-CS-Ex1.54-Y2 Repeater by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (loop powered), SMART fire alarm input, Current input 1 mA ... 20 mA, Housing width: 20 mm, Number of ch...
View full detailsKCD2-RR2-Ex1.SP Resistance Repeater by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (Power Rail), Resistance and RTD input (Pt100, Pt500, Pt1000), Resistance output, Accuracy 0.1 %, Line f...
View full detailsKFD0-CS-Ex2.54 Repeater by Pepperl-Fuchs
Pepperl-Fuchs2-channel isolated barrier, 24 V DC supply (loop powered), SMART fire alarm input, Current input 1 mA ... 20 mA, Up to SIL 3 acc. to IEC/EN 61508, ...
View full detailsKFD0-CS-Ex1.54 Repeater by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (loop powered), SMART fire alarm input, Current input 1 mA ... 20 mA, Up to SIL 3 acc. to IEC/EN 61508, ...
View full details