Pepperl-Fuchs
KFD2-RCI-1 Solenoid Driver by Pepperl-Fuchs
Pepperl-Fuchs1-channel signal conditioner, 24 V DC supply (Power Rail), Output 20.4 mA at 13.5 V DC, 19 V DC ... 30 V DC input, Test pulse immunity, Line fault ...
View full detailsKFD2-SL-4 Solenoid Driver, Power Amplifier by Pepperl-Fuchs
Pepperl-Fuchs4-channel signal conditioner, 24 V DC supply (Power Rail), Output 600 mA per channel, Logic inputs, Common safety-oriented disable input, Line faul...
View full detailsKFD2-SL2-Ex2.B Solenoid Driver by Pepperl-Fuchs
Pepperl-Fuchs2-channel isolated barrier, 24 V DC supply (Power Rail), Output 45 mA at 11.7 V DC, Logic input, non-polarized, Up to SIL 2 acc. to IEC/EN 61508, H...
View full detailsKFD2-SL2-Ex2 Solenoid Driver by Pepperl-Fuchs
Pepperl-Fuchs2-channel isolated barrier, 24 V DC supply (Power Rail), Output 45 mA at 11.7 V DC, Logic input, non-polarized, Line fault detection (LFD), Up to S...
View full detailsKCD0-SD3-Ex1.1245.SP Solenoid Driver by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 12 V DC, Test pulse immunity, Housing width 12.5 mm, Connection v...
View full detailsKFD2-SLD-Ex2.1545-Y1 Solenoid Driver by Pepperl-Fuchs
Pepperl-Fuchs2-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 45 mA at 15 V DC, Line fault transparency (LFT), Test pulse immunity, Hous...
View full detailsKFD2-SLD-Ex2.1245-Y1 Solenoid Driver by Pepperl-Fuchs
Pepperl-Fuchs2-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 45 mA at 12 V DC, Line fault transparency (LFT), Test pulse immunity, Hous...
View full detailsKFD2-SLD-Ex2.1045-Y1 Solenoid Driver by Pepperl-Fuchs
Pepperl-Fuchs2-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 45 mA at 10 V DC, Line fault transparency (LFT), Test pulse immunity, Hous...
View full detailsKFD2-SLD-Ex1.13100 Solenoid Driver by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (Power Rail), Logic input, Output 100 mA at 13 V DC, Alternating outputs for the operation of solenoids ...
View full detailsKFD0-SD2-Ex2.1245 Solenoid Driver by Pepperl-Fuchs
Pepperl-Fuchs2-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 12 V DC, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm, ...
View full detailsKFD0-SD2-Ex2.1045 Solenoid Driver by Pepperl-Fuchs
Pepperl-Fuchs2-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 10 V DC, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm, ...
View full detailsKCD2-SLD-Ex2.1545-Y1.SP Solenoid Driver by Pepperl-Fuchs
Pepperl-Fuchs2-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 45 mA at 15 V DC, Line fault transparency (LFT), Test pulse immunity, Hous...
View full detailsKCD2-SLD-Ex2.1545-Y1 Solenoid Driver by Pepperl-Fuchs
Pepperl-Fuchs2-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 45 mA at 15 V DC, Line fault transparency (LFT), Test pulse immunity, Hous...
View full detailsKCD2-SLD-Ex1.1045 Solenoid Driver by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 45 mA at 10 V DC, Line fault transparency (LFT), Test pulse immunity, Hous...
View full detailsKCD0-SD3-Ex2.1545-Y1.SP Solenoid Driver by Pepperl-Fuchs
Pepperl-Fuchs2-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 15 V DC, Test pulse immunity, Housing width 12.5 mm, Connection v...
View full detailsKCD0-SD3-Ex2.1545-Y1 Solenoid Driver by Pepperl-Fuchs
Pepperl-Fuchs2-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 15 V DC, Test pulse immunity, Housing width 12.5 mm, Housing widt...
View full detailsKFD2-VM-Ex1.35.L Solenoid Driver by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (Power Rail), Output 15.3 V DC at 17 mA, 3 logic inputs with AND/OR logic, Service port for isolator fun...
View full detailsKFD0-SD2-Ex1.1180 Solenoid Driver by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 80 mA at 11 V DC, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm, ...
View full detailsKFD0-SD2-Ex1.10100 Solenoid Driver by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 100 mA at 10 V DC, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm,...
View full detailsKCD2-SLD-Ex1.1245 Solenoid Driver by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 45 mA at 12 V DC, Line fault transparency (LFT), Test pulse immunity, Hous...
View full detailsKCD2-SLD-Ex1.1065 Solenoid Driver by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (bus or loop powered), Output 65 mA at 10 V DC, Line fault transparency (LFT), Test pulse immunity, Hous...
View full detailsKCD0-SD3-Ex1.1245 Solenoid Driver by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 12 V DC, Test pulse immunity, Housing width 12.5 mm, Up to SIL 3 ...
View full detailsKCD0-SD3-Ex1.1045 Solenoid Driver by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 10 V DC, Test pulse immunity, Housing width 12.5 mm, Up to SIL 3 ...
View full details