pepperl-fuchs
KFD0-CS-Ex2.54 Repeater by Pepperl-Fuchs
Pepperl-Fuchs2-channel isolated barrier, 24 V DC supply (loop powered), SMART fire alarm input, Current input 1 mA ... 20 mA, Up to SIL 3 acc. to IEC/EN 61508, ...
View full detailsKFD0-LGH Place Holder Barrier by Pepperl-Fuchs
Pepperl-FuchsK-System place holder module, Housing width 20 mm, Marshalling for field and control side circuits, Configurable via plug-in jumpers Brand : Pepp...
View full detailsKFD0-LGH-5T Place Holder Barrier by Pepperl-Fuchs
Pepperl-FuchsK-System place holder module, Housing width 20 mm, Marshalling for field and control side circuits, Configurable via plug-in jumpers, Two additiona...
View full detailsKFD0-LGH-GN Place Holder Barrier by Pepperl-Fuchs
Pepperl-FuchsK-System place holder module, Housing width 20 mm, Marshalling for field and control side circuits, Configurable via plug-in jumpers Brand : Pepp...
View full detailsKFD0-LGH-Y34868 Place Holder Barrier by Pepperl-Fuchs
Pepperl-FuchsK-System place holder module, Housing width 20 mm, Marshalling for field and control side circuits, No electrical function: empty housing Brand :...
View full detailsKFD0-LGH-Y39343 Place Holder Barrier by Pepperl-Fuchs
Pepperl-FuchsK-System place holder module, Housing width 20 mm, Marshalling for field and control side circuits, Configurable via DIP switches and plug-in jumpe...
View full detailsKFD0-RO-2 Relay Module by Pepperl-Fuchs
Pepperl-Fuchs2-channel signal conditioner, 24 V DC supply (loop powered), Logic input 15 V DC ... 30 V DC, non-polarized, Relay contact output, Up to SIL 3 acc....
View full detailsKFD0-RO-Ex2 Relay Module by Pepperl-Fuchs
Pepperl-Fuchs2-channel isolated barrier, 24 V DC supply (loop powered), Logic input 15 V DC ... 30 V DC, non-polarized, Relay contact output, Up to SIL 3 acc. t...
View full detailsKFD0-RSH-1.1D.F1 Relay Module by Pepperl-Fuchs
Pepperl-Fuchs1-channel signal conditioner, 24 V DC supply (loop powered), Logic input 19 V DC ... 26.5 V DC, non-polarized, Relay contact output for de-energize...
View full detailsKFD0-RSH-1.1E.1 Relay Module by Pepperl-Fuchs
Pepperl-Fuchs1-channel signal conditioner, 24 V DC supply (loop powered), Logic input 19 V DC ... 26.5 V DC, non-polarized, Relay contact output for energized t...
View full detailsKFD0-RSH-1.4S.PS2 Relay Module by Pepperl-Fuchs
Pepperl-Fuchs1-channel signal conditioner, 24 V DC supply (loop powered), Logic input 20 V DC ... 26.5 V DC, non-polarized, Fail-safe relay contact output for d...
View full detailsKFD0-SCS-1.55 SMART Current Driver/Repeater by Pepperl-Fuchs
Pepperl-Fuchs1-channel signal conditioner, 24 V DC supply (loop powered), Current input/output 4 mA ... 20 mA, HART-IP or transmitter power supply, Low voltage ...
View full detailsKFD0-SCS-Ex1.55 SMART Current Driver/Repeater by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (loop powered), Current input/output 4 mA ... 20 mA, HART-IP or transmitter power supply, Low voltage dr...
View full detailsKFD0-SD2-Ex1.10100 Solenoid Driver by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 100 mA at 10 V DC, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm,...
View full detailsKFD0-SD2-Ex1.1180 Solenoid Driver by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (loop powered), Current limit 80 mA at 11 V DC, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm, ...
View full detailsKFD0-SD2-Ex2.1045 Solenoid Driver by Pepperl-Fuchs
Pepperl-Fuchs2-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 10 V DC, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm, ...
View full detailsKFD0-SD2-Ex2.1245 Solenoid Driver by Pepperl-Fuchs
Pepperl-Fuchs2-channel isolated barrier, 24 V DC supply (loop powered), Current limit 45 mA at 12 V DC, Up to SIL 3 acc. to IEC/EN 61508, Housing width: 20 mm, ...
View full detailsKFD0-TR-1 RTD Converter by Pepperl-Fuchs
Pepperl-Fuchs1-channel signal conditioner, 24 V DC supply (loop powered), 2- or 3-wire Pt100 RTD input, Output 4 mA ... 20 mA, temperature linearization selecta...
View full detailsKFD0-TR-Ex1 RTD Converter by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (loop powered), 2- or 3-wire Pt100 RTD input, Output 4 mA ... 20 mA, temperature linearization selectabl...
View full detailsKFD0-TT-Ex1 Thermocouple Converter by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (loop powered), Thermocouple input, Output 4 mA ... 20 mA, Internal cold junction compensation, Sensor b...
View full detailsKFD2-CRG2-1.D Transmitter Power Supply by Pepperl-Fuchs
Pepperl-Fuchs1-channel signal conditioner, 24 V DC supply (Power Rail), Input 2-wire and 3-wire transmitters and 2-wire current sources, Output 0/4 mA ... 20 mA...
View full detailsKFD2-CRG2-Ex1.D Transmitter Power Supply by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (Power Rail), Input 2-wire and 3-wire transmitters and 2-wire current sources, Output 0/4 mA ... 20 mA, ...
View full detailsKFD2-DWB-1.D Rotation Speed Monitor by Pepperl-Fuchs
Pepperl-Fuchs1-channel signal conditioner, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Input frequency 1 mHz ... 12 kHz, 2 relay contact outputs, ...
View full detailsKFD2-DWB-Ex1.D Rotation Speed Monitor by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Input frequency 1 mHz ... 5 kHz, 2 relay contact outputs, Sta...
View full detailsKFD2-EB2 Power Feed Module by Pepperl-Fuchs
Pepperl-FuchsInterface for Power Rail, Supply current ? 4 A, Replaceable fuse, Relay contact output, reversible, LED status indication Brand : Pepperl-Fuchs ...
View full detailsKFD2-EB2.R4A.B Redundant Power Feed Module by Pepperl-Fuchs
Pepperl-FuchsInterface for Power Rail, Used for redundant configuration, Supply current ? 4 A, Replaceable fuse, Relay contact output, reversible, LED status in...
View full detailsKFD2-EB2.R4A.B.SP Redundant Power Feed Module by Pepperl-Fuchs
Pepperl-FuchsInterface for Power Rail, Used for redundant configuration, Supply current ? 4 A, Replaceable fuse, Relay contact output, reversible, LED status in...
View full detailsKFD2-EB2.SP Power Feed Module by Pepperl-Fuchs
Pepperl-FuchsInterface for Power Rail, Supply current ? 4 A, Replaceable fuse, Relay contact output, reversible, LED status indication, Connection via spring te...
View full detailsKFD2-ER-1.W.LB Conductive Switch Amplifier by Pepperl-Fuchs
Pepperl-Fuchs1-channel signal conditioner, 24 V DC supply (Power Rail), Level sensing input, Adjustable range 1 k? ... 150 k?, Relay contact output, Fault relay...
View full detailsKFD2-ER-2.W.LB Conductive Switch Amplifier by Pepperl-Fuchs
Pepperl-Fuchs2-channel signal conditioner, 24 V DC supply (Power Rail), Level sensing input, Adjustable range 1 k? ... 150 k?, Relay contact output, Adjustable ...
View full detailsKFD2-ER-Ex1.W.LB Conductive Switch Amplifier by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (Power Rail), Level sensing input, Adjustable range 1 k? ... 150 k?, Relay contact output, Fault relay c...
View full detailsKFD2-GS-1.2W Current/Voltage Trip Value by Pepperl-Fuchs
Pepperl-Fuchs1-channel signal conditioner, 24 V DC supply (Power Rail), Current and voltage input, 2 relay contact outputs, Programmable high/low alarm, Configu...
View full detailsKFD2-GUT-1.D Temperature Converter with Trip Values by Pepperl-Fuchs
Pepperl-Fuchs1-channel signal conditioner, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Redundant TC input, Current output 0/...
View full detailsKFD2-GUT-Ex1.D Temperature Converter with Trip Values by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Redundant TC input, Current output 0/4 ...
View full detailsKFD2-HLC-Ex1.D HART Loop Converter by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (Power Rail), HART field device input with transmitter power supply, Usable as signal splitter (1 input ...
View full detailsKFD2-HLC-Ex1.D.2W HART Loop Converter by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (Power Rail), HART field device input with transmitter power supply, Usable as signal splitter (1 input ...
View full detailsKFD2-PT2-Ex1 Potentiometer Converter by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (Power Rail), Potentiometer input, Voltage output 0 V ... 10 V, Lead resistance compensation adjustment,...
View full detailsKFD2-PT2-Ex1-1 Potentiometer Converter by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (Power Rail), Potentiometer input, Voltage output 0 V ... 5 V, Lead resistance compensation adjustment, ...
View full detailsKFD2-PT2-Ex1-5 Potentiometer Converter by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (Power Rail), Potentiometer input, Current output 4 mA ... 20 mA, Lead resistance compensation adjustmen...
View full detailsKFD2-RCI-1 Solenoid Driver by Pepperl-Fuchs
Pepperl-Fuchs1-channel signal conditioner, 24 V DC supply (Power Rail), Output 20.4 mA at 13.5 V DC, 19 V DC ... 30 V DC input, Test pulse immunity, Line fault ...
View full detailsKFD2-RSH-1.2D.FL2 Relay Module by Pepperl-Fuchs
Pepperl-Fuchs1-channel signal conditioner, 24 V DC supply, Logic input 19 V DC ... 26.4 V DC, Recommended connectable voltage 8 V DC ... 60 V DC, Relay contact ...
View full detailsKFD2-RSH-1.2D.FL3 Relay Module by Pepperl-Fuchs
Pepperl-Fuchs1-channel signal conditioner, 24 V DC supply, Logic input 19 V DC ... 26.4 V DC, Recommended connectable voltage 50 V AC ... 230 V AC, 60 V DC ... ...
View full detailsKFD2-RSH-1.2E.L2 Relay Module by Pepperl-Fuchs
Pepperl-Fuchs1-channel signal conditioner, 24 V DC supply, Logic input 19 V DC ... 26.4 V DC, Recommended connectable voltage 8 V DC ... 60 V DC, Relay contact ...
View full detailsKFD2-RSH-1.2E.L3 Relay Module by Pepperl-Fuchs
Pepperl-Fuchs1-channel signal conditioner, 24 V DC supply, Logic input 19 V DC ... 26.4 V DC, Recommended connectable voltage 50 V AC ... 230 V AC, 60 V DC ... ...
View full detailsKFD2-SCD2-Ex1.LK SMART Current Driver by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 650 ? load, HART-IP and valve positioner, Line fault detection (LFD),...
View full detailsKFD2-SCD2-Ex2.LK SMART Current Driver by Pepperl-Fuchs
Pepperl-Fuchs2-channel isolated barrier, 24 V DC supply (Power Rail), Current output up to 650 ? load, HART-IP and valve positioner, Line fault detection (LFD),...
View full detailsKFD2-SH-Ex1 Switch Amplifier by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (Power Rail), Input for approved dry contacts or SN/S1N sensors, Relay contact output, Fault indication ...
View full detailsKFD2-SH-Ex1.T.OP Switch Amplifier by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (Power Rail), Input for approved dry contacts or SN/S1N sensors, Active voltage output, Relay contact ou...
View full details