pepperl-fuchs
KFD2-UT2-Ex1 Universal Temperature Converter by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Current output 0/4 mA ... 20 mA, Sink o...
View full detailsKFD2-UT2-Ex2 Universal Temperature Converter by Pepperl-Fuchs
Pepperl-Fuchs2-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Usable as signal splitter (1 input and ...
View full detailsKFD2-UT2-Ex2-1 Universal Temperature Converter by Pepperl-Fuchs
Pepperl-Fuchs2-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Usable as signal splitter (1 input and ...
View full detailsKFD2-VM-Ex1.35.L Solenoid Driver by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (Power Rail), Output 15.3 V DC at 17 mA, 3 logic inputs with AND/OR logic, Service port for isolator fun...
View full detailsKFD2-VR-Ex1.12 Voltage Repeater by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input 0 V ... 9 V, Voltage output 0 V ... 9 V, Housing width: 20 mm, Number of cha...
View full detailsKFD2-VR-Ex1.18 Voltage Repeater by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input 0 V ... 12 V, Voltage output 0 V ... 12 V, Housing width: 20 mm, Number of c...
View full detailsKFD2-VR-Ex1.19 Voltage Repeater by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input -10 V ... 10 V, Voltage output -10 V ... 10 V, Housing width: 20 mm, Number ...
View full detailsKFD2-VR-Ex1.19-Y109129 Voltage Repeater by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input -10 V ... 10 V, Transmission frequency up to 50 kHz, Voltage output -10 V .....
View full detailsKFD2-VR2-Ex1.500M Voltage Repeater by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input 0 mV ... ± 500 mV, Voltage output 0 mV ... ± 500 mV, Selectable up/downscale...
View full detailsKFD2-VR2-Ex1.50M Voltage Repeater by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input 0 mV ... ± 50 mV, Voltage output 0 mV ... ± 50 mV, Selectable up/downscale s...
View full detailsKFD2-VR4-Ex1.26 Voltage Repeater by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (Power Rail), Voltage input 0 V ... -20 V, Vibration sensor inputs, Voltage/current field supply, Voltag...
View full detailsKFD2-WAC2-1.D Strain Gauge Converter by Pepperl-Fuchs
Pepperl-Fuchs1-channel signal conditioner, 24 V DC supply (Power Rail), Strain gauge input (full or half bridge), Output 0 mA ... ± 20 mA or 0 V ... ± 10 V, 2 r...
View full detailsKFD2-WAC2-Ex1.D Strain Gauge Converter by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 24 V DC supply (Power Rail), Strain gauge input (full or half bridge), Output 0 mA ... ± 20 mA or 0 V ... ± 10 V, 2 rel...
View full detailsKFU8-CRG2-1.D Transmitter Power Supply by Pepperl-Fuchs
Pepperl-Fuchs1-channel signal conditioner, Universal usage at different power supplies, Input 2-wire and 3-wire transmitters and 2-wire current sources, Output ...
View full detailsKFU8-CRG2-Ex1.D Transmitter Power Supply by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, Universal usage at different power supplies, Input 2-wire and 3-wire transmitters and 2-wire current sources, Output 0/...
View full detailsKFU8-DW-1.D Rotation Speed Monitor by Pepperl-Fuchs
Pepperl-FuchsSpeed monitoring up to 40 kHz, 1 pre-select value with relay output and LED indicator, 2-, 3-, 4-wire and NAMUR sensors as well as rotary encoder c...
View full detailsKFU8-DWB-1.D Rotation Speed Monitor by Pepperl-Fuchs
Pepperl-Fuchs1-channel signal conditioner, Universal usage at different power supplies, Dry contact or NAMUR inputs, Input frequency 1 mHz ... 12 kHz, 2 relay c...
View full detailsKFU8-GUT-1.D Temperature Converter with Trip Values by Pepperl-Fuchs
Pepperl-Fuchs1-channel signal conditioner, Universal usage at different power supplies, Thermocouple, RTD, potentiometer or voltage input, Redundant TC input, C...
View full detailsKFU8-GUT-Ex1.D Temperature Converter with Trip Values by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, Universal usage at different power supplies, Thermocouple, RTD, potentiometer or voltage input, Redundant TC input, Cur...
View full detailsKFU8-SR-1.3L.V Switch Amplifier, Timer Relay by Pepperl-Fuchs
Pepperl-Fuchs1-channel signal conditioner, Universal usage at different power supplies, 3-wire PNP/NPN sensor or push-pull input, 2 relay contact outputs, Adjus...
View full detailsKFU8-SR-Ex1.W Switch Amplifier by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, Universal usage at different power supplies, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (L...
View full detailsKFU8-SR-Ex1.W.LB Switch Amplifier by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, Universal usage at different power supplies, Dry contact or NAMUR inputs, Relay contact output, Fault relay contact out...
View full detailsKFU8-SR-Ex2.W Switch Amplifier by Pepperl-Fuchs
Pepperl-Fuchs2-channel isolated barrier, Universal usage at different power supplies, Dry contact or NAMUR inputs, Relay contact output, Line fault detection (L...
View full detailsKFU8-UFC-1.D Frequency Converter with Trip Values by Pepperl-Fuchs
Pepperl-Fuchs1-channel signal conditioner, Universal usage at different power supplies, Input for 2- or 3-wire sensors, NAMUR sensors or dry contacts, Input fre...
View full detailsKFU8-UFC-1.D.FA Frequency Converter with Trip Values by Pepperl-Fuchs
Pepperl-Fuchs1-channel signal conditioner, Universal usage at different power supplies, Input for 2- or 3-wire sensors, NAMUR sensors or dry contacts, Input fre...
View full detailsKFU8-UFC-Ex1.D Frequency Converter with Trip Values by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, Universal usage at different power supplies, Input for NAMUR sensors or dry contacts, Input frequency 1 mHz ... 5 kHz, ...
View full detailsKFU8-UFT-2.D Frequency Converter with Direction and Synchronization Monitor by Pepperl-Fuchs
Pepperl-Fuchs2-channel signal conditioner, Universal usage at different power supplies, Dry contact or NAMUR inputs, Input frequency 1 mHz ... 1 kHz, Current ou...
View full detailsKFU8-UFT-Ex2.D Frequency Converter with Direction and Synchronization Monitor by Pepperl-Fuchs
Pepperl-Fuchs2-channel isolated barrier, Universal usage at different power supplies, Dry contact or NAMUR inputs, Input frequency 1 mHz ... 1 kHz, Current outp...
View full detailsKFU8-USC-1.D Signal Converter with Trip Value by Pepperl-Fuchs
Pepperl-Fuchs1-channel signal conditioner, Universal usage at different power supplies, Scaleable current or voltage input, Current or voltage output, Relay con...
View full detailsKHA6-SH-Ex1 Switch Amplifier by Pepperl-Fuchs
Pepperl-Fuchs1-channel isolated barrier, 115/230 V AC supply, Input for approved dry contacts or SN/S1N sensors, Relay contact output, Fault indication output, ...
View full detailsKLD0-SAA Voltage Adjustment Module by Pepperl-Fuchs
Pepperl-FuchsFieldConnex® Fieldbus, Module for use with Segment Protectors, Series voltage reducing module, Removable terminals, Polarity reversal protected, In...
View full detailsKLD2-FBPS-1.12.220 Fieldbus Power Supply by Pepperl-Fuchs
Pepperl-FuchsFieldConnex® Fieldbus, Fieldbus power supply with low voltage for compact plants also in island mode, Output: 12 ... 13 V/220 mA, For battery or so...
View full detailsKLD2-FBPS-1.25.360 Fieldbus Power Supply by Pepperl-Fuchs
Pepperl-FuchsFieldConnex® Fieldbus, Fieldbus power supply for fieldbus power hub, Output: 25 ... 27 V/360 mA, For most fieldbus applications, High-power trunk f...
View full detailsKT-MB-DMA Advanced Diagnostic Kit by Pepperl-Fuchs
Pepperl-FuchsFieldConnex® Fieldbus, Advanced diagnostic kit for retrofitting advanced diagnostics, Comprehensive diagnostics for the fieldbus physical layer, Mo...
View full detailsKT-MB-GT2AD.FF Diagnostic Gateway Kit by Pepperl-Fuchs
Pepperl-FuchsFieldConnex® Fieldbus, Diagnostic gateway kit with Ethernet, FF-H1 interface for advanced diagnostics, System integration kit for Advanced Diagnost...
View full detailsLB1001A Digital Input by Pepperl-Fuchs
Pepperl-Fuchs2 channels, Dry contact or NAMUR inputs, Installation in Zone 2 or safe area, Galvanic isolation between channels and the bus, Explosion protection...
View full detailsLB1003A Frequency / Counter Input by Pepperl-Fuchs
Pepperl-Fuchs1-channel, Input for frequency, counter, direction of rotation, Installation in Zone 2 or safe area, Digital input max. 15 kHz, Explosion protectio...
View full detailsLB1008A Digital Input by Pepperl-Fuchs
Pepperl-Fuchs8-channel, Dry contact or NAMUR inputs, Installation in Zone 2 or safe area, Positive or negative logic selectable, Explosion protection: Ex ic, Co...
View full detailsLB1009A Digital Input by Pepperl-Fuchs
Pepperl-Fuchs8-channel, Inputs Ex ic, Installation in Zone 2 or safe area, Dry contact or NAMUR inputs, Explosion protection: Ex ic, Connection: NAMUR sensor, C...
View full detailsLB1101A Digital Input by Pepperl-Fuchs
Pepperl-Fuchs2 channels, Inputs Ex ia, Mounting in Zone 2, Class I/Div.2 or in the safe area, Dry contact or NAMUR inputs, Explosion protection: Ex ia, Connecti...
View full detailsLB1103A Frequency / Counter Input by Pepperl-Fuchs
Pepperl-Fuchs1-channel, Input Ex ia, Mounting in Zone 2, Class I/Div.2 or in the safe area, Input for frequency, counter, direction of rotation, Explosion prote...
View full detailsLB1108A Digital Input by Pepperl-Fuchs
Pepperl-Fuchs8-channel, Inputs Ex ia, Mounting in Zone 2, Class I/Div.2 or in the safe area, Dry contact or NAMUR inputs, Explosion protection: Ex ia, Connectio...
View full detailsLB1109A Digital Input by Pepperl-Fuchs
Pepperl-Fuchs8-channel, Inputs Ex ia, Mounting in Zone 2, Class I/Div.2 or in the safe area, Dry contact or NAMUR inputs, Explosion protection: Ex ia, Connectio...
View full detailsLB2016E Digital Output with Position Feedback by Pepperl-Fuchs
Pepperl-Fuchs1-channel, 1 digital output, 2 digital inputs, Installation in Zone 2 or safe area, Inputs and output Ex ic, Explosion protection: Ex ic Brand : ...
View full detailsLB2017E Digital Output with Position Feedback by Pepperl-Fuchs
Pepperl-Fuchs1-channel, 1 digital output, 2 digital inputs, Installation in Zone 2 or safe area, Inputs and output Ex ic, Explosion protection: Ex ic Brand : ...
View full detailsLB2116E Digital Output with Position Feedback by Pepperl-Fuchs
Pepperl-Fuchs1-channel, 1 digital output, 2 digital inputs, Mounting in Zone 2, Class I/Div.2 or in the safe area, Inputs and output Ex ia, Explosion protection...
View full detailsLB2117E Digital Output with Position Feedback by Pepperl-Fuchs
Pepperl-Fuchs1-channel, 1 digital output, 2 digital inputs, Mounting in Zone 2, Class I/Div.2 or in the safe area, Inputs and output Ex ia, Explosion protection...
View full detailsLB3002A2 HART Transmitter Power Supply, Input Isolator by Pepperl-Fuchs
Pepperl-Fuchs1-channel, Power supply for 2- or 3-wire transmitters with 4 mA ... 20 mA, Installation in Zone 2 or safe area, Supply circuit 15 V (20 mA), Explos...
View full details